posted on 2025-08-26, 07:21authored byJohannes Koslowski, Enrique Campbell, Michael Stapf, Heinrich Gürtler, Michel Gunkel, Regina Gnirss
<p dir="ltr">A measurement campaign of wastewater temperatures was carried out in a section of the Berlin wastewater network. These results were used to carry out a temperature simulation using the EPA SWMM-Fork SWMM-HEAT. It was shown that a good agreement between measurements and simulations is possible for predominantly residential areas, even if the network was only moderately thermally calibrated (MAE ≤ 1 °C).</p><p dir="ltr">This paper was presented at the 21st Computing and Control in the Water Industry Conference (CCWI 2025) at the University of Sheffield (1st - 3rd September 2025).</p>
History
Methodology, headings and units
Headings and units are explained in the files
Policy
The data complies with the institution and funders' policies on access and sharing
Sharing and access restrictions
The uploaded data can be shared openly
Data description
The file formats are open or commonly used
Responsibility
The depositor is responsible for the content and sharing of the attached files
Ethics
There is no personal data or any that requires ethical approval